Self-Generating Coach Systems

Electrical Engineering Train Lighting & AC Coaches Chapter 1/9 12 min read Source: Verified Source
हिन्दी में पढ़ें

Create a free account to track your reading, save important notes and practise this topic.

Train lighting on Indian Railways began with axle-driven dynamos in 1930. Today, four systems remain in use: axle-driven 110V DC, Mid-On-Generation (415V 3-phase generation, 110V AC utilisation), and two End-On-Generation variants (415V and 750V 3-phase generation, both with 110V AC utilisation). New coach construction now standardises on the 110V system.

Axle-Generation System (Self-Generating Coaches)

Each coach generates its own power via a dynamo/brushless alternator driven from the coach axle through flat or V-belts — the coach is electrically independent of its neighbours. All D.C. dynamos have since been replaced by brushless alternators, which are more reliable and need less maintenance since they have no commutator or brushes to wear.

End-On-Generation (EOG)

For premium, fully air-conditioned services (Rajdhani/Shatabdi-type trains), the connected load is too large for per-coach self-generation — diesel-generator-equipped power cars at each end of the rake feed the entire train instead.

Coach TypeCountLoad per coach (KW)Total (KW)
AC 3-Tier840.00320.00
AC 2-Tier634.75208.50
AC First115.7515.75
AC Pantry276.75153.50
AC Power Car (working)249.0098.00

This real Rajdhani rake example (Mumbai Central–New Delhi) totals ~800 KW connected load across 19 coaches. Applying a diversity factor of 0.7, maximum demand works out to 560 KW.

🎯
Exam Focus — 415V vs 750V EOG
Older EOG rakes used THREE power cars at 415V, 3-phase, 125 KW DG sets. To reduce this to just TWO power cars (first and last vehicle of the rake) while still feeding the whole train, DG capacity was increased to 250 KW and generation voltage raised to 750V — specifically to overcome voltage drop over the length of the feeding system. A 750V/415V step-down transformer then feeds the actual AC equipment.
💡
Memory Aid — BOG Alternator Difference
Self-generating-coach brushless alternators have NO rotor windings (just a toothed wheel) — less efficient but simple. Power-car (BOG-system) brushless alternators DO have windings on BOTH stator and rotor — more efficient, needed for the much larger loads they must supply.