HOG System Troubleshooting

Electrical Engineering Train Lighting & AC Coaches Chapter 3/9 10 min read Source: Verified Source
हिन्दी में पढ़ें

Create a free account to track your reading, save important notes and practise this topic.

This chapter covers real fault-diagnosis tables for HOG (Head-On-Generation) power supply issues — the actual indication lamps, switches, and fallback procedures staff use when HOG supply fails.

750V Supply Not Available

Converter Output Tripping

Indicated by the faulty converter LED glowing at H3/H4. The converter automatically attempts to restart within 25 seconds after 3 consecutive trips. If it still doesn't start after this automatic reset, press the reset switch and hold it for a long time, then wait 3 minutes for the output-available lamp to glow. If the converter still won't turn on after that manual reset, staff must switch over to operating the EOG DG set instead, treating it as a genuine converter failure.

🎯
Exam Focus — Two Different Time Values
Two specific, easily-confused time values: the automatic restart attempt happens within 25 SECONDS of 3 consecutive trips. The manual reset, by contrast, requires waiting 3 MINUTES for the output-available lamp after a long-press of the reset switch. Exam questions often swap these two values.

If the loco pilot reports a persistent 'Waiting for command' message on the converter display, and this is traced to the UIC coupler not being properly connected, the fix must wait until the next halt/station — lower the pantograph first, then check the UIC coupler connection.

Feeder Not Starting

💡
Memory Aid — The Universal Fallback
Across almost every HOG fault scenario in the real manual, the ultimate fallback is the same: switch to operating the EOG DG set. HOG failures don't strand the train electrically — they just mean falling back to the older, power-car-based EOG generation the coach is still wired for.